Certificate of constancy of performance
                                               1608 CPR P029
In compliance with Regulation 305/2011/EU of the European Parliament and of the Council of 9 March 2011 (the Construction Products
Regulation or CPR), this certificate applies to the construction products:


                                             Steel lighting columns
                                       whose characteristics are detailed in the attached annex,

                                                          produced by or for


                                                   Pali Campion Srl
                           Via Alcide De Gasperi, 45/B 45025 Fratta Polesine RO-IT
                                             and produced in the manufacturing plant(s)

                                                    Fratta Polesine RO-IT
This certificate attests that all provisions concerning the assessment and verification of performance described in Annex ZA of the
standard

                                                     EN 40-5:2002
under system 1 are applied and that
                  the product fulfils all the prescribed requirements set out above.
This certificate was first issued on 18/03/2005 and will remain valid as long as the test method and/or factory production control
requirements included in the harmonised standard, used to assess the performance of the declared characteristics, do not change, and
the product, and the manifacturing conditions in the plant are not modified significantly.


                                                                                       The Director
     Current issue:       12/03/2021
                                                                                     Roberto Pieroncini




                                                                                                                              Pagina 1


ATTACHMENT 1 TO CERTIFICATE                         1608 CPR P029
                                               Characteristics for
                        Steel lightning columns according to EN 40-5
                     Name                             Total height                      Configuration
                                                          (m)                      (position of the lantern)
Welded columns with rectangular/square section
Welded stepped cylindrical columns
Welded tapered columns with circular section           Up to 20 m                            Post top

Welded tapered columns with octagonal or
polygonal section
Welded columns with rectangular/square section
Welded stepped cylindrical columns
Welded tapered columns with circular section           Up to 18 m                          With brackets

Welded tapered columns with octagonal or
polygonal section



                                                 Characteristic
                                               Wind reference load (m/s)
                                                                                       2
Resistance to horizontal loads                 Windage area to wind of the lantern (m )
                                               Weight of the lantern (kg)
                                               Maximum horizontal deflection (%)
Performance under vehicle impact               Classe 0
Durability                                     Hot dip zinc coating to EN ISO 1461

first issue:     18/03/2005                                                              The Director
current issue:   12/03/2021                                                            Roberto Pieroncini




                                                                                                               Pagina 2


ATTACHMENT 2 TO CERTIFICATE                           1608 CPR P029
                                               Characteristics for
                        Steel lightning columns according to EN 40-5
                  Declared performance under vehicle impact according to EN 12767:2019
                  Name                             Design condition           Total Height      Configuration
                                               (according to EN 40-3-3)           (m)        (position of the lantern)
Conical columns with foundation: SAVE50   Tubular columns with Mup 8,89kNm       5m                 Post top
Conical columns with foundation: SAVE51   Tubular columns with Mup 8,89kNm       5m            With bracket 1 m
Conical columns with foundation: SAVE52   Tubular columns with Mup 8,89kNm       5m            With bracket 2 m
Conical columns with foundation: SAVE60   Tubular columns with Mup 8,89kNm       6m         Post top extended 1 m
Conical columns with foundation: SAVE61   Tubular columns with Mup 8,89kNm       6m           With bracket 1x1 m
Conical columns with foundation: SAVE62   Tubular columns with Mup 8,89kNm       6m           With bracket 1x2 m
Conical columns with foundation: SAVE70   Tubular columns with Mup 8,89kNm       7m         Post top extended 2 m
Conical columns with foundation: SAVE71   Tubular columns with Mup 8,89kNm       7m           With bracket 2x1 m
Conical columns with foundation: SAVE72   Tubular columns with Mup 8,89kNm       7m           With bracket 2x2 m


                                                    Characteristic
Performance under vehicle impact              Speed class: 70 Km/h
according to EN 12767, as reported in:        Energy absorption class: LE
Report 0028_ME_HRB_18
Report 0030_ME_HRB_18                         Safety Class: C
and as per update standard reported in:       ASI: 0,6
Report 0081_ME_HRB_20_1                       THIV: 24 km/h
                                              Backfill type: standard aggregates – S type
                                              ATLANTECH Lux Small Device
Foundation
                                              In accordance to the Installation Manual:
                                              ATLANTECH LUX Installation Manual
Collapse mode                                 Separation mode – SE class
Direction class                               Single directional – SD class
Detached elements with a mass greater         No
than 2 kg

first issue:      18/03/2005                         The Director
current issue:    12/03/2021                       Roberto Pieroncini




                                                                                                                Pagina 3


CONFIGURATION LIGTHING COLUMN SAVE 5m - 6m - 7m




                                                  Pagina 4


ATTACHMENT 2 TO CERTIFICATE                           1608 CPR P029
                                                Characteristics for
                        Steel lightning columns according to EN 40-5
                  Declared performance under vehicle impact according to EN 12767:2019
                  Name                            Design condition               Total         Configuration
                                                (according to EN 40-3-3)         Height     (position of the lantern)
                                                                                  (m)
Conical columns with foundation: SAVE80    Tubular columns with Mup 10,07kNm     8m                Post top
Conical columns with foundation: SAVE81    Tubular columns with Mup 10,07kNm     8m           With bracket 1 m
Conical columns with foundation: SAVE82    Tubular columns with Mup 10,07kNm     8m           With bracket 2 m
Conical columns with foundation: SAVE90    Tubular columns with Mup 10,07kNm     9m        Post top extended 1 m
Conical columns with foundation: SAVE91    Tubular columns with Mup 10,07kNm     9m          With bracket 1x1 m
Conical columns with foundation: SAVE92    Tubular columns with Mup 10,07kNm     9m          With bracket 1x2 m
Conical columns with foundation: SAVE100   Tubular columns with Mup 10,07kNm     10 m      Post top extended 2 m
Conical columns with foundation: SAVE101   Tubular columns with Mup 10,07kNm     10 m        With bracket 2x1 m
Conical columns with foundation: SAVE102   Tubular columns with Mup 10,07kNm     10 m        With bracket 2x2 m


                                                   Characteristic
Performance under vehicle impact              Speed class: 50 Km/h - 70 Km/h
according to EN 12767, as reported in:
                                              Energy absorption class: HE
Report 0027_ME_HRB_18
Report 0030_ME_HRB_18                         Safety class: C
and as per update standard reported in:       ASI: 0,8
Report 0081_ME_HRB_20_1                       THIV: 27 km/h
                                              Backfill type: standard aggregates – S type
                                              ATLANTECH Lux Plus Device
Foundation
                                              In accordance to the Installation Manual:
                                              ATLANTECH LUX Installation Manual
Collapse mode                                 No separation collapse mode – NS class
Direction class                               Single directional – SD class
Detached elements with a mass greater         Yes, the lamp
than 2 kg

first issue:      18/03/2005
                                                    The Director
current issue:    12/03/2021
                                                  Roberto Pieroncini



                                                                                                               Pagina 5


CONFIGURATION LIGTHING COLUMN SAVE 8m - 9m - 10m




                                                   Pagina 6